Section 11 Backward Compatibility
11.1 Backward Compatibility to the 2020-10 Release
The following changes have been made to the default settings from build 2020-10-AF. Some of these have specific commands to revert behaviour, for others these can be reverted by setting defaults to pre 2023. These changes are summarised in Table 11.1 below. Changes specific to models with Sub-Grid Sampling (SGS) are summarised in Table 11.2 and changes specific to models with SGS and High Resolution Outputs in Table 11.3.
Description of Change | Section | Backward Compatibility Command |
---|---|---|
Change to quadtree handling of inertial parallel to boundary | Section 5.4 |
|
Upper limiting Manning’s n in Wu turbulence calculation | Section 4.7.1 |
|
Duplicate Materials IDs | Section 2.7.2 |
No specific command - |
Duplicate Soil IDs | Section 2.7.3 |
No specific command - |
Duplicate SA Boundaries | Section 5.9.2 |
No specific command - |
HPC Weir Approach | Section 4.2 |
|
HPC SX Momentum | Section 5.2 |
|
HPC Boundary Approach | Section 5.6 |
|
Initial Moisture and Green-Ampt infiltration | Section 2.3.9 |
No specific command - |
Drop Support for 2d_bc QT Point Boundaries (Classic/HPC) | Section 5.7 |
No specific command - |
Drop Support for 2d_bc HQ Point Boundaries (Classic/HPC/Quadtree) | Section 5.8 |
No specific command - |
Description of Change | Section | Backward Compatibility Command |
---|---|---|
SGS Approach | Section 2.2.2 |
|
SGS Depth Output | Section 2.2.1 |
|
Mapping of partially wet SGS cells | Section 2.2.1 |
|
Description of Change | Section | Backward Compatibility Command |
---|---|---|
High Resolution raster output interpolation method | Section 2.2.5 |
|
High resolution thin breaklines | Section 2.2.6 |
|
As always, it is recommended when switching to a new Build with an established model that test runs be carried out and comparisons made between the old and new Builds (subtracting the two maximum water level (h) data sets and reviewing any differences is an easy way to do this). If you have any queries on the comparison outcomes, require clarification or more detail on any of the points below, please email support@tuflow.com.