Message 11019

TUFLOW FV
TUFLOW FV - STM
Available since version: 2026.2.0
WARNING 11019 - Depending on group model selection sediment grain density may need to be set.

Description

The grain (particle) density has not been set for this sediment fraction. Depending on the model selections, grain density may be required to correctly compute sediment transport rates.

Suggestions

Add the Particle Density == command to the sediment fraction definition in the sediment transport control file. If grain density is not required by the selected models this warning can be ignored.