Message 10354
TUFLOW FV
Available since version: 2026.2.0
Description
The weir crest elevation has not been set for this structure. Flux Function == Weir requires an absolute weir crest elevation to be specified via the Properties == command. This value cannot be omitted or defaulted.
Suggestions
Provide the weir crest elevation via the Properties == command for this structure.
If a crest elevation relative to the bed is preferred, switch the Flux Function == to Weir_dz instead. These flux types accept a delta-Z offset and will default to zero if the elevation property is not supplied.